Ip Telephone Terminal Basic Data Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
Program 15 : Extension, Basic Setup

15-05 : IP Telephone Terminal Basic Data Setup

Level
IN
Description
Use Program 15-05 : IP Telephone Terminal Basic Data Setup to set up the basic settings for an IP
telephone.
Input Data
Extension Number
Item
Item
No.
01
Terminal Type
0 = NGT
1 = H.323
2 = SIP
3 = MEGACO
4 = SIP-MLT
02
IP Phone Fixed
MAC address
Port Assign-
00-00-00-00-00-00 ~
ment
FF-FF-FF-FF-FF-FF
04
Nickname
Up to 48 characters
07
Using IP
0.0.0.0 ~
Address
255.255.255.255
09
Call procedure
0 ~ 65535
port
15
CODEC Type
1 = Type 1
2 = Type 2
3 = Type 3
4 = Type 4
5 = Type 5
16
Authentication
Up to 24 characters
Password
Programming Manual
Input Data
Default
-
00-00-00-
00-00-00
No setting
-
-
1
None
SL1000/SL1100
Maximum four digits (SL1000)
Maximum eight digits (SL1100)
Related
Description
Program
MAC Address of reg-
15-05-01
istered SIP MLT
phone is stored
and/or can input the
MAC address of an
SIP MLT phone so
when it comes on-
line it is provided
with the extension in
which the MAC ad-
dress matches.
Nickname section on
15-05-17
Invite message.
Example :
Extension 100 has a
Nickname set to
PAUL.
Extension 101 has
command 15-05-17
set to Nickname.
The inbound call to
extension 101, from
100, shows PAUL.
15-05-01
15-05-01
Assign the CODEC
84-24
Type of the SIP MLT.
84-11
15-05-01
Assign the authenti-
15-05-01
cation password for
SIP single line tele-
phones.
Program
15
Note
2-127