ISSUE 1.0
Program 80 : Basic Hardware Setup for System
Level
IN
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is de-
fined by the combination of 32 Basic Tones.
Input Data
Service Tone Number
Item No.
01
Repeat Count
Item No.
02
Basic Tone Number
03
Duration Count
04
Gain Level (dB)
Basic Tone No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
Programming Manual
Item
Unit Number
Item
Table 2-13 Basic Tones
Frequency (Hz)
420
520
580
660
700
800
880
1050
430
440 / 480
480 / 620
440
-- Reserve --
520 / 650
650 / 780
780 / 1040
520 / 650
80-01 : Service Tone Setup
01 ~ 64
Input Data
0 ~ 255 (0 = Endless)
1 ~ 8
Input Data
0 ~ 33
(0 = No Tone)
(33 = Default Time Slot)
0 ~ 255 (0, 100 ~ 25500 ms)
0 ~ 63 (- 15.5 ~ + 15.5)
Level (dB)
- 13 / - 13
- 13 / - 13
-19 / -13
-19 / -13
-19 / -13
-13 / -19
SL1000/SL1100
Program
80
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 13
- 13
-16
-