Did Basic Data Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
Level
IN
Description
Use Program 22-09 : DID Basic Data Setup to define the basic setting of Dial-In incoming calls for
each trunk group.
Input Data
Trunk Group Number
Item No.
Item
01
Expected Number of Digits
Enter the number of digits the
table expects to receive from the
Telco. Use this program to make
the system compatible with 3-
and 4-digit DID service. If ISDN
trunks, we analyze the last digits
that are set here. If it is T-1 or
analog DID, it analyzes the first
digits that are assigned here.
02
Received Vacant Number Op-
eration
Use this option to enable or dis-
able Vacant Number Intercept.
03
Sub-Addressing Mode
04
DID Receiving Mode for ISDN
05
Local Code Digits
(Only Overlap Receiving Mode)
06
Local Code
(Only Overlap Receiving Mode)
07
Pilot Code
(Only Overlap Receiving Mode)
08
T302 Time-out Operation
(Only Overlap Receiving Mode)
Conditions
None
Feature Cross Reference
• Direct Inward Dialing (DID)
Programming Manual
Program 22 : Incoming Call Setup

22-09 : DID Basic Data Setup

Input Data
1 ~ 8
0 = Disconnect (Cut)
1 = Transfer (Refer to
tercept Ring Group. on page
0 = Extension # Specify (Intercom)
1 = DID Conversion Table
0 = Enbloc Receiving
1 = Overlap Receiving
0 ~ 15 (0 = No Local Code)
Dial (maximum 16 digits)
Dial (1 digit : 0 ~ 9)
0 = Disconnect (Cut)
1 = Transfer (Refer to
tercept Ring Group. on page
2 = Search
01 ~ 25
Program 22-12 : DID In-
2-258)
Program 22-12 : DID In-
2-258)
SL1000/SL1100
Program
22
Default
2
0
0
0
0
No setting
No setting
0
2-253

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1100

Table of Contents