T1 Trunk Timer Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item
01
Answer Signal Detection Time (Loop)
02
Answer Signal Detection Time (Ground)
03
Answer Signal Detection Time (DID)
04
Answer Signal Detection Time (E&M)
05
Answer Signal Detection Time (OPX)
06
Clear Signal Detection Time (Loop)
07
Clear Signal Detection Time (Ground)
08
Clear Signal Detection Time (DID)
09
Answer Signal Detection Time (E&M)
10
Clear Signal Detection Time (OPX)
11
Ringing Signal Detection Time (Loop)
12
Ringing Signal Detection Time (Ground)
13
Ringing Signal Detection Time (DID)
14
Ringing Signal Detection Time (E&M)
15
Ringing Signal Detection Time (OPX)
16
Ringing Signal Stop Detection Time (Loop)
17
Ringing Signal Stop Detection Time
(Ground)
18
Ringing Signal Stop Detection Time (DID)
19
Ringing Signal Stop Detection Time (E&M)
20
Ringing Signal Stop Detection Time (OPX)
21
Loop Current Detection Time (Loop)
22
Loop Current Detection Time (Ground)
23
Loop Current Detection Time (DID)
24
Loop Current Detection Time (E&M)
25
Loop Current Detection Time (OPX)
26
DP Break Send Time (ALL)
27
DP Make Send Time (ALL)
28
DP InterDigit Send Time (ALL)
29
HookFlash Send Time (Loop)
30
HookFlash Send Time (Ground)
31
HookFlash Send Time (DID)
Programming Manual
Name
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)

81-08 : T1 Trunk Timer Setup

Input Data
SL1000/SL1100
Program
81
Default
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
40 (160 ms)
15 (60 ms)
10 (40 ms)
7 (700 ms)
5 (500 ms)
5 (500 ms)
5 (500 ms)
2-445