7.11.1 Diagnostic Plotter Page
New for the PTP 300 Series is the system administration diagnostic plotter facility see Figure
82.
The diagnostic plotter allows the system administrator to view the cascading histogram data
in an easily accessible graphical form. The plot always displays three traces, maximum,
minimum and mean by default. The diagnostic selector allows the user to select the various
categories of histogram.
The histograms that are available are:
•
Vector Error
•
Rx Power
•
Tx Power
•
Signal Strength Ratio
•
Link Loss
•
Rx Data Rate
•
Tx Data Rate
•
Aggregate Data Rate
The diagnostic plotter uses a novel time representation in the x-axis which compresses the
timeline of the plot without sacrificing resolution.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299
Figure 82 - Diagnostic Plotter
146
7 Web Page Reference