Figure 32 - Correct And Incorrect Rj45 Cable Dressing - Motorola PTP 300 Series User Manual

Point-to-point wireless bridge
Hide thumbs Also See for PTP 300 Series:
Table of Contents

Advertisement

CAUTION
Do not dress the RJ45 cables too tightly, as this may make the connections
unreliable. Figure 32 shoes the correct and incorrect ways to dress RJ45 cables
when connected to the PIDU Plus.
CAUTION
The PIDU Plus is not waterproof and should be mounted away from sources of
moisture. If mounted outdoors, the unit should be mounted in a rain proof enclosure,
preferably ventilated.
It is also recommended that you fit a drip loop on the PIDU Plus to ODU cable to ensure that
any moisture that runs down the cable into the cabinet or enclosure cannot enter the PIDU
Plus. This is shown in Figure 33. The network connection and mains cable should be treated
in the same way if there is a risk that they can carry moisture to the PIDU Plus.
4Gon www.4Gon.co.uk info@4gon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299

Figure 32 - Correct and Incorrect RJ45 Cable Dressing

63
6 Installation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptp 500 series

Table of Contents