Motorola PTP 300 Series User Manual page 97

Point-to-point wireless bridge
Hide thumbs Also See for PTP 300 Series:
Table of Contents

Advertisement

Incompatible Master and Slave
A non-zero value indicates that the master and slave ends of the wireless link are different
hardware products, or have different software versions. Note that it is very unusual to detect
this because incompatible units will normally fail to establish a wireless link. However, some
combinations may establish a partial wireless link and detect this situation. Note that a non-
zero value may generate an SNMP trap and/or SMTP email alert.
SNTP Synchronization failed
This warning indicates that SNTP has been enabled but that the unit is unable to synchronize
with the specified SNTP server. Section 7.10.8 "SNTP (Simple Network Time Protocol)"
explains how to configure SNTP. Note that a change of state may generate an SNMP trap
and/or SMTP email alert.
Line Of Sight Mode Inactive
This warning is displayed if Line Of Sight Mode is set to "LOS" but the link range exceeds 10
km (6.2 miles). The link drops back to "NLOS" modes and data rates.