The two PTP 300 Series bridges units are arranged in a master and slave relationship. The
roles of the units in this relationship are displayed in the page title. The master unit will always
have the title '- Master', and the slave will always have '- Slave' appended to the 'Systems
Status' page title.
The following attributes are displayed on the status page:
Link Name
The link name is allocated by the system administrator and is used to identify the equipment
on the network. The link name attribute is limited to a maximum size of 63 ASCII characters.
Link Location
The link location is allocated by the system administrator and can be used as a generic
scratch pad to describe the location of the equipment or any other equipment related notes.
The link location attribute is limited to a maximum size of 63 ASCII characters.
Software Version
The attribute describes the version of software installed on the equipment. The format of the
attributes is FFSSS-XX-YY where FF is the frequency variant (5.4 or 5.8 GHz), SSS is the
System Release, XX is the major release version and YY is the minor release version.
Hardware Version
The hardware version attribute contains all the combined hardware version information. The
attribute is formatted as DXX-RAA.BB-Z where DXX contain the version of the digital card, AA
is the major hardware version number, BB is the minor hardware version number and Z
describes the antenna type which can be I (integrated) or C (connectorized).
Region Code
The region code is used by the system to constrain the wireless to operate within regulatory
regime of the particular country. The region code is encoded in the product license key. If the
operator wishes to change region code, a new license key must be obtained from Motorola or
the local point-to-point distributor / system integrator.
Elapsed Time Indicator
The elapsed time indicator attribute presents the total time in years, days, hours, minutes and
seconds since the last system restart. The system can restart for several reasons, for
example commanded reboot from the system reboot web page, or a power cycle of the
equipment.
Ethernet Link Status:
Current status of the Ethernet link. A state of 'Up' with a green background indicates that an
Ethernet link is established. A state of 'Down' with a red background indicates that the
Ethernet link is not established.
Ethernet Speed and Duplex
The negotiated speed and duplex setting of the Ethernet interface. The speed setting is
specified in Mbps.
Full Duplex data transmission means that data can be transmitted in both directions on a
signal carrier at the same time. For example, on a local area network with a technology that
has full duplex transmission; one workstation can be sending data on the line while another
workstation is receiving data.