Dell PowerEdge M820 Owner's Manual page 105

Hide thumbs Also See for PowerEdge M820:
Table of Contents

Advertisement

Error Code
Message Information
Action
LNK2700
Message
Details
Action
MEM0000
Message
Details
Action
MEM0001
Message
LCD Message
Details
Action
MEM0002
Message
Details
Action
MEM0003
Message
Details
Action
MEM0004
Message
Review System Log or front panel for additional information.
The <name> LAN heartbeat is lost.
CMC has lost network connection.
Check network cable and network connections.
Persistent correctable memory errors detected on a memory
device at location(s) <location>.
This is an early indicator of a possible future uncorrectable
error.
Re-seat the memory modules. If the issue persists, see
Getting Help
.
Multi-bit memory errors detected on a memory device at
location(s) <location>.
Multi-bit memory error on <location>. Re-seat memory.
The memory module has encountered a uncorrectable error.
System performance may be degraded. The operating
system and/or applications may fail as a result.
Re-seat the memory modules. If the issue persists, see
Getting
Help.
Parity memory errors detected on a memory device at
location <location>.
The memory is operational. This an early indicator of a
possible future uncorrectable error.
Re-seat the memory modules. If the issue persists, see
Getting
Help.
Stuck bit memory error detected on a memory device at
location <location>.
This is an early indicator of a possible future uncorrectable
error.
Re-seat the memory modules. If the issue persists, see
Getting
Help.
Memory device at location <location> is disabled.