Error Code
Message Information
Action
PDR1001
Message
LCD Message
Details
Action
PDR1002
Message
Details
Action
PDR1016
Message
LCD Message
Details
Action
PDR1024
Message
LCD Message
Details
Action
PST0128
Message
LCD Message
Details
If unintended, verify drive installation. Remove and re-seat
the indicated disk. If the issue persists, see
Fault detected on drive <number> in disk drive bay <bay>.
Fault detected on drive <number> in disk drive bay <bay>.
Check drive.
The controller detected a failure on the disk and has taken
the disk offline.
Re-seat the failed drive. If the issue persists, see
Help.
A predictive failure detected on drive <number> in disk drive
bay<bay>.
The controller received a SMART error from the drive. The
drive is operational but needs replacement.
The drive will need replacement at the next service window.
Drive <number> is removed from disk drive bay <bay>.
Drive <number> removed from disk drive bay <bay>. Check
drive.
The controller detected that the drive was removed.
Verify drive installation. Re-seat the failed drive. If the issue
persists, see
Getting
Help.
Drive mismatch detected for drive <number> in disk drive
bay <bay>.
Drive mismatch detected for drive <number> in bay <bay>.
Install correct drive type.
The installed disk does not meet the array requirements, for
example a SATA disk may not operate in an array containing
SAS drives.
Verify that the disk meets the array requirements.
No memory is detected.
No memory is detected. Inspect memory devices.
System BIOS was unable to detect memory in the system .
Getting
Help.