Error Code
Message Information
Action
SEL1204
Message
LCD Message
Details
Action
SEL1209
Message
Details
Action
SEL1211
Message
Details
Action
SEL1300
Message
Details
Action
SEL1302
Message
Details
Action
SEL1304
Message
134
Reboot the management controller or iDRAC. Cycle system
input power. If problem persists call support.
An unknown system hardware failure detected.
Unknown system hardware failure.
If the system event log failed to initialize platform status and
failure events are not captured. Some management software
will not report platform exceptions.
Re-configure system to minimum supported configuration. If
issues persists, contact support.
The platform event filter action failed.
System policies or permissions may prevent the action from
executing. If configured, the system does not execute the
action on a platform event (such as power down, cycle,
interrupt, and send alert).
Review platform event configuration.
The time-stamp clock could not be synchronized.
The time stamp on system event log events may not
correlate to the system time.
Cycle system input power. If problem persists, contact
support.
No bootable media found.
System setup displays the system boot order. The local video
screen may also show additional information. (IPMI sensor
type code 1eh - offset 00h).
Check system boot settings. Check if mass storage controller
configuration settings are applicable.
Non-bootable diskette detected.
The disk in the drive is not formatted correctly or does not
contain the necessary operating system files.
Replace diskette with a bootable disk.
The PXE server not found.

Advertisement