Error Code
Message Information
LCD Message
Details
Action
PWR1001
Message
LCD Message
Details
Action
PWR1002
Message
Details
Action
PWR1003
Message
Details
Action
PWR1004
Message
Details
Action
PWR1005
Message
PSU redundancy degraded. Check PSU cables.
The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Check the event log for power supply failures. Review
system configuration and power consumption.
The system performance was degraded.
System performance degraded. Check PSUs and system
configuration.
To avoid shutdown, system performance has been degraded.
Review system configuration and system logs for thermal or
environmental failures and warnings.
The system performance degraded because of thermal
protection.
To avoid shutdown, system performance has been degraded.
Review system configuration and system logs for thermal or
environmental failures and warnings.
The system performance degraded because cooling capacity
has changed.
The current power supply configuration does not meet the
platform requirements to enable redundancy. If a power
supply fails the system may shutdown.
If unintended, review system configuration and power
consumption and install power supplies accordingly. Check
power supply status for failures.
The system performance degraded because power capacity
has changed.
The system may power down or operate in a performance
degraded state.
Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.
The system performance degraded because the user-
defined power capacity has changed.
125

Advertisement

Table of Contents
loading

Table of Contents