Error Code
Message Information
CPU0203
Message
LCD Message
Details
Action
CPU0204
Message
LCD Message
Details
Action
CPU0700
Message
LCD Message
Details
Action
4.
If the issue persists, see
CPU <number> <name> voltage is greater than the upper
critical threshold.
CPU <number> <name> voltage is outside of range. Re-seat
CPU.
High voltages may be the result of problem with the voltage
regulator or a problem with the processor. Elevated voltages
may result in damage to the processor or other system
electrical components. The system may power down.
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
CPU <number> <name> voltage is outside of range.
CPU <number> <name> voltage is outside of range. Re-seat
CPU.
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
1.
Turn system off and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn system on.
4.
If the issue persists, see
CPU <number> initialization error detected.
CPU <number> initialization error detected. Power cycle
system.
System BIOS was unable to initialize the processor.
1.
Turn system off and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn system on.
Getting
Help.
Getting
Help.
Getting
Help.