Dell PowerEdge M820 Owner's Manual page 116

Hide thumbs Also See for PowerEdge M820:
Table of Contents

Advertisement

Error Code
Message Information
Action
PCI3010
Message
Details
Action
PCI3012
Message
Details
Action
PCI3014
Message
Details
Action
PDR0001
Message
LCD Message
Details
Action
PDR0002
Message
Details
Action
PDR0016
Message
LCD Message
Details
116
Cycle input power, update component drivers, remove and
reinstall the device at the next service window.
A non-fatal IO error detected on a component at bus
<bus>device<device>function <func>.
System performance may be degraded.
Cycle input power, update component drivers, remove and
reinstall the device at the next service window.
The QuickPath Interconnect (QPI) width degraded.
System performance may be degraded. The bus is not
operating at maximum speed or width.
Reset the system, if the problem persists reinstall processors.
A non-fatal PCIe error detected on a component at slot
<number>.
System performance may be degraded.
Cycle input power, update component drivers, remove and
reinstall the device at the next scheduled service time.
Fault detected on drive <number>.
Fault detected on drive <number>. Check drive.
The controller detected a failure on the disk and has taken
the disk offline.
Remove and re-seat the failed disk. If the issue persists, see
Getting
Help.
A predictive failure detected on drive <number>.
The controller received a SMART error from the drive. The
drive is operational but needs replacement.
The drive will need replacement at the next service window.
Drive <number> is removed.
Drive <number> is removed. Check drive.
The controller detected a drive removal.

Advertisement