Table 1: Maximum Device Wire Length and MIn./Max. Current Draw (Continued)
Device
Speaker Siren (60-528 or 13-060)
*Maximum current draw for the SnapCards does not include the load which may be applied to
their auxiliary DC supply.
9
Note
When installing SuperBus 2000 RF Receiver Modules, the Antenna Tamper feature must be set to off
(see REPORTING—GLOBAL in the "Programming" section).
Table 2 describes the total system wire lengths allowed for all SuperBus 2000 devices when
installing systems using unshielded or shielded cable. (The maximum wire length for individual
devices is shown in Table 1)
Table 2: Total System Wire Length Allowed
18-gauge, unshielded
18-gauge, shielded
22-gauge, unshielded
22-gauge, shielded
After determining panel location, run all necessary wires to that location using the guidelines in
Table 3.
Device
AC Power Transformer
Earth Ground
Telephone (RJ-31X)
Detection Devices
Speakers
SuperBus 2000 Devices
Interrogator 200 AVM Power and Microphone 4-conductor, 22-gauge, shielded (see Table 1)
2-Wire Smoke Detectors

Mounting the Panel

Use the following procedure to mount the panel to the wall or wall studs.
Make sure you are free of static electricity whenever you work on the panel with the cover
!
open. To discharge any static, first touch the metal panel chassis, then stay in contact with
the chassis when touching the circuit board. Using an approved grounding strap is recom-
mended.
Caution
To mount the panel (see Figure 2):
1.
Remove the panel door and remove the necessary wiring knockouts. Be careful not to dam-
age the circuit board.
2.
Feed all wires through wiring knockouts and place the panel in position against the wall.
3.
Level the panel and mark the top and bottom mounting holes.
4.
Install anchors where studs are not present.
5.
Partially insert screws into the two top mounting hole locations, then hang the panel on the
two screws.
WWW.DIYALARMFORUM.COM
Max. Wire Length
Standby mA
to Panel
Draw
18 ga.—100 ft.
0 mA
Wire Type
Total System Wire
4,000 ft.
3,000 ft.
4,000 ft.
3,000 ft.
Table 3: Wire Requirements
2-conductor, 18-gauge, 25 feet max
Single conductor, 16-gauge solid, 25 feet max
4-conductor
2- or 4-conductor, 22-gauge, 1,000 feet max
2- or 4-conductor, 18-gauge, 2,500 feet max
(based on 30 ohms max loop resistance includ-
ing device)
2-conductor, 18-gauge, 100 feet max
4-conductor, 22- or 18-gauge (see Table 1)
2-conductor, 22-gauge, 330 feet max
2-conductor, 18-gauge, 830 feet max
(based on 10-ohms max loop resistance plus a
2k-ohm, end-of-line resistor)
Alarm mA Draw
500 mA
Wire Requirements
Concord 4 Series Systems