Cross-Zoning - GE Concord 4 Series Installation Instructions Manual

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

No.
Name
26
Fire
24-hour fire, rate-of-rise heat, and smoke sensors.
Hardwire Output Module (HOM) lamp control or other
27
Output Module
customer feature. ‡
HOM, PIR motion sensor, sound sensor or pressure
28
Output Module
mat. ‡
29
Auxiliary
Freeze sensor.
HOM, PIR motion sensor, sound sensor or pressure
32
Output Module
mat.‡
33
Siren
Wireless Siren Supervision. ‡
34
Gas
Carbon monoxide (CO) Gas Detectors ‡
Local Instant
35
Police (Day
Local alarm in levels 1 and 2. Report to CS in level 3. Police
Zone)
38
Auxiliary
Water sensor ‡
Note: Check marks (
) represent characteristics present in a group.
* This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
† Sounds instant police siren if two or more sensors are tripped within 4 minutes. Otherwise sensors are followers to delayed
sensors. If Alarm Verification is on, group 18 functions like group 17.
‡ This group has not been investigated by UL.
§ This group is required for UL-listed residential fire alarm applications.
Note
Cross-Zoning is not recom-
mended for exit/entry zones.
Each zone has the ability to
individually protect the
intended area. (e.g. motion
detector patterns overlap).
91
Table B1: Sensor Group Characteristics (Continued)
Application

Cross-Zoning

Cross-Zone (Alarm Verify) refers to two different Group 10-20 sensors that must be tripped
within four minutes of each other to report an alarm to the central station. The diagram in the fig-
ure below shows the path of a person walking from the kitchen to the living room. When the per-
son is detected walking through the kitchen, the motion sensor in the kitchen is tripped, sounding
a local alarm. If motion is detected by the living room motion sensor within four minutes, an
alarm report will be sent to the central station.
D i n i n g
K i t c h e n
R o o m
L i v i n g
R o o m
D e t e c t i o n P a t h / K i t c h e n M o t i o n S e n s o r
D e t e c t i o n P a t h / L i v i n g R o o m
M o t i o n S e n s o r
P a t h o f P e r s o n W a l k i n g
WWW.DIYALARMFORUM.COM
Alarm
Fire
Instant
Silent
Instant
Silent
Instant
Auxiliary Instant
Silent
Instant
Silent
Instant
Auxiliary Instant
Instant
Auxiliary Instant
B e d r o o m
B e d r o o m
B e d r o o m
M o t i o n S e n s o r
Delay
(level 3
only)
Concord 4 Series Systems
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3