Sensors Menu - GE Concord 4 Series Installation Instructions Manual

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

UL 98 Options (0702)
This setting determines whether the panel complies with UL 98
requirements (4-hour trouble beep restart, 4-hour backup battery test,
4-hour smoke (group 26) zone supervisory).
Note
For UL Listed installations, this feature must be on.
Global Fire (0703)
This setting determines whether or not sirens in all partitions sound
(on) if any partition activates a fire alarm.
Silent Panic (0704)
This setting determines whether touchpad police panic alarms are
audible (off) or silent (on).
Siren Verify (0710)
This setting determines whether or not the panel supervises the panel
speaker terminals (7–8). When this feature is on, the panel will indicate a
trouble condition if no speaker is connected to panel speaker terminals.
Note
For UL Listed installations, Siren Verify must be set to on.
51
The following describes the settings that appear under

Sensors Menu

The
menu gives you access to the following settings:
SENSORS
lets you add (learn) hardwire zones, wireless sensors, and wireless touch-
LEARN SENSORS
pads into panel memory.
lets you "name" the sensors and zones you have added to the system.
SENSOR TEXT
lets you delete zones and sensors from panel memory.
DELETE SENSORS
lets you view and, if desired, change a sensor group or partition assignment.
EDIT SENSORS
You can also identify whether a zone is wireless or hardwire, whether it is configured as
Normally Closed (N/C) or Normally Open (N/O), or if the zone is a touchpad.
Sensor
Hardwire Zones
Wireless Sensors
WWW.DIYALARMFORUM.COM
Siren Options-Global (Default = off)
To turn UL 98 Options off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Siren Options-Global (Default = off)
To turn Global Fire off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Siren Options-Global (Default = off)
To turn Silent Panic off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on).
OFF/ON
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
SIREN OPTIONS—PARTITION 1
Siren Options-Partition 1 (Default = off)
To turn Siren Verify off or on:
1.
With the display showing
(current setting), press 1 (off) or 2 (on).
ON
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Table 6: How to Trip Sensors
Steps to Trip Sensor
Start with the zone in its "normal" state, then trip the zone into
its alarm state. A normally closed door, for example, should be
closed when you begin the Learn Sensors process. To trip the
zone, open the door.
Follow the instructions included with each sensor.
UL 98 OPTIONS OFF/ON
GLOBAL FIRE OFF/ON
GLOBAL SILENT PANIC
.
SIREN VERIFY OFF/
Concord 4 Series Systems