RF Supv Report (06014)
This setting determines whether the panel sends daily or weekly
reports to the central monitoring station when the panel detects a
supervisory condition in a wireless device.

Swinger Limit (06015)

This setting determines the maximum number of times (1–2) a sensor or zone can go into
alarm (during a single arming period) before the panel automatically bypasses that sensor
or zone. This feature only applies to sensors or zones in groups 00–20, 29, 34, 35, or 38.
When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm.
When set to 2, the panel waits until a sensor or zone has caused a second alarm (during the
same arming period) before bypassing it. At any setting, the automatic bypass is logged
into the event buffer.
A bypassed sensor or zone will be cleared (automatically unbypassed) if the system
receives no further activations from that sensor or zone over the next 48–50 hours.
Changing the arming level also clears all automatically bypassed sensors and zones and
resets the Swinger Limit count on all sensors and zones.
Aux Power Fail (06016)
When this setting is on, the panel sends a report to the central mon-
itoring station if the 12 VDC power outputs on the panel and/or
SuperBus 2000 2-Amp Power Supply fail.
Note
If this feature is on and the AC Failure and Low CPU Battery features
are both on, the panel sends AC failure and low backup battery reports
for the SuperBus 2000 2-Amp Power Supply.
Ground Fault (06017)
When this setting is ON, the panel will annunciate and send a report
to the central monitoring station if it detects current flow between
the panel's circuitry and the chassis. This indicates that a short to
earth ground exists somewhere in the system.
Note
This feature must be on if hardware smoke sensors are used in this sys-
tem.
Opening Reports (06100 - 06600)
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
Note
To use this feature, the Open/Close Reports settings under the
menu must be turned on for the specific CS Phone or Pager number.
47
The following describes the settings that appear under
WWW.DIYALARMFORUM.COM
To set RF Supv Report to daily or weekly:
1.
With the display showing
(current setting), press 1 (daily) or 2
WEEKLY
(weekly). The display flashes the entered setting.
2.
Press # and the display shows the new setting.
To turn Program Report on or off:
1.
With the display showing
(current setting), press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.
To turn Ground Fault on or off:
1.
With the display showing GROUND FAULT OFF/
ON (current setting), press 1 (off) or 2 (on).
2.
Press # and the display shows the new setting.
REPORTING—PARTITION 1-6.
Reporting-Partition 1-6 (Default = off)
To turn Opening Reports off or on:
1.
With the display showing
OFF/ON
The display flashes the entered setting.
PHONES
2.
Press # and the display shows the new setting.
Reporting-Global (Default = weekly)
RF SUPV REPORT DAILY/
Reporting-Global (Default = 1)
To set the Swinger Limit:
1.
With the display showing
SWINGER LIMIT n
setting), press the desired
number (1–2). The display
flashes the entered setting.
2.
Press # and the display
shows the new setting.
Reporting-Global (Default = on)
AUX POWER FAIL ON/OFF
Reporting-Global (Default = on)
OPENING REPORTS
(current setting), press 1 (off) or 2 (on).