Appendix B: Reference Tables - GE Concord 4 Series Installation Instructions Manual

Security systems
Hide thumbs Also See for Concord 4 Series:
Table of Contents

Advertisement

Appendix B:
Reference
Tables
No.
Name
00
Fixed Panic
24-hour audible fixed emergency buttons.
01
Portable Panic
24-hour audible portable emergency buttons.
02
Fixed Panic
24-hour silent fixed emergency buttons.
03
Portable Panic
24-hour silent portable emergency buttons.
24-hour auxiliary sensor, such as Pendant Panic or
04
Fixed Auxiliary
holdup button.
24-hour auxiliary emergency button. Siren shutoff
05
Fixed Auxiliary
confirms CS report.
Portable Auxil-
06
24-hour portable auxiliary alert button.
iary
Portable Auxil-
24-hour portable auxiliary button. Siren shutoff con-
07
iary
firms CS report.
Special belongings, such as gun cabinets and wall
08
Special Intrusion
safes.
09
Special Intrusion Special belongings (i.e. gun cabinets and wall safes.) Police
Entry and exit doors that require a standard delay
10
Entry/Exit Delay
time.
Garage doors and entrances that require an extended
11
Entry/Exit Delay
delay time. *
Driveway gates and entrances that require a twice
12
Entry/Exit Delay
extended delay time. *
13
Instant Perimeter Exterior doors and windows.
14
Instant Interior
Interior doors.
15
Instant Interior
Interior PIR motion sensors. *
16
Instant Interior
Interior doors.
17
Instant Interior
PIR motion sensors. *
18
Instant Interior
Instant Interior Cross-Zone# PIR motion sensors. * †
Interior doors that initiate a delay before going into
19
Delayed Interior
alarm. *
PIR motion sensors that initiate a delay before going
20
Delayed Interior
into alarm. *
Local Instant
24-hour local alarm zone protecting anything that
21
Interior
opens and closes.
Local Delayed
Same as group 21, plus activation initiates a delay
22
Interior
before going into alarm.
Local Instant
24-hour local alarm zone protecting anything that
23
Auxiliary
opens and closes. ‡
Local Instant
24-hour local alarm zone protecting anything that
24
Auxiliary
opens and closes. Sirens shut off at restoral. *
Local Special
Notify the user when a door is opened. Sounds emit
25
Chime
from a local annunciator. *
Concord 4 Series Systems
Table B1: Sensor Group Characteristics
Application
WWW.DIYALARMFORUM.COM
Alarm
Delay
Police
Instant
Police
Instant
Silent
Instant
Silent
Instant
Auxiliary Instant
Auxiliary Instant
Auxiliary Instant
Auxiliary Instant
Police
Instant
Standard
Police
Standard
Police
Extended
Twice
Police
Extended
Police
Instant
Police
Follower
Police
Follower
Police
Follower
Police
Follower
Police
Follower
Police
Standard
Police
Standard
Police
Instant
Police
Standard
Auxiliary Instant
Auxiliary Instant
Special
Instant
Chime
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
2, 3
3
3
3
3
3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: