Note
The installer must verify the
compatibility between this
panel and the central station
receiver(s) being used.
Note
For 24-hour backup, exter-
nal power drain is limited to
90 mA (during normal
standby condition) using a
4.5 Ah battery, or 190 mA
continuous using a 7.0 Ah
battery.
Planning the
Installation
Concord 4 Series Systems
Phone Test Freq. set to 1
High Level Rpts set to on
Low Level Rpts set to on
Comm. Failure set to on
RF Tx Timeout set to 4 hours

Central Station Reporting

The panel has been tested with the following central station receivers using SIA and Contact ID
reporting formats:
CS-5000 Central Station Receiver
Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2
Osborne Hoffman Central Station Receiver

UL Canada Listed Installations

This section describes the requirements for CUL (UL Canada) Listed installations.

Canadian Standards CSA Certified Accessories

Residential Burglary Alarm System Unit (ULC Subject C1023-1974)

Basic system as described for "UL 1023 Listed Installations" plus:
Hardwire Magnetic Contact (13-068 or 13-071) or Wireless Learn Mode Door/Window Sen-
sor (60-362)
Siren Timeout set to 5 minutes or more

Residential Fire Warning System Control Unit (ULC-S545-M89)

Basic system as described for "UL 985 Listed Installations" plus:
Hardwire Smoke Detector: System Sensor models 2400 or 2400TH learned into Sensor
Group 26, or Sentrol (ESL) models 429AT, 521B, or 521BXT learned into sensor group 26
Wireless Smoke Sensor 60-506-319.5 or 60-848-02-95 learned into sensor group 26
Immediate Trouble Beeps set to on
RF TX Timeout set to 4 hours (if system includes SuperBus 2000 RF Transceiver and wire-
less smoke sensors)
Siren timeout set to 5 minutes or more.

California State Fire Marshall Listed Installations

Same as Household Fire Warning System (UL 985), plus:
SMOKE VERIFY must be set to off
This section describes system capabilities to help you get familiar with the system. "Appendix
A" provides planning sheets with tables that let you record the hardware and programming con-
figuration of the system. Fill in all necessary information ahead of time to help prepare for sys-
tem installation.
The panels have the following capabilities:
Capabilities
Zones
Partitions
Bus Devices
User Codes

Standard Panel

The following describe the basic panel (out-of-box) hardware capabilities.
Power: Input for an AC step-down, plug-in style transformer.
Auxiliary Power Output: Output that supplies 9 to 14 VDC with up to 1 amp for bus
devices and hardwired detectors, such as smoke and motion detectors.