Chapter 16: Multiple Degree of Match Inspection
16-1 Outline
Using the gray search function, the IV-C35M can detect up to 128 workpieces whose
Purpose
captured image exceeds the required degree of match with the reference image.
Position measurement of workpieces having complicated density conditions, that
Application
could not be measured by conventional binary conversion and density processing.
Reference image
Example
[Measurement results]
- Number of images detected
- Degree of match, density (average/absolute difference), and detected coordinates
Multiple Degree of Match Inspection
16-1
Four
workpieces
detected