Setting For Serial Communications; Station No - Sharp IV-C35M User Manual

Compact color image sensor camera
Hide thumbs Also See for IV-C35M:
Table of Contents

Advertisement

21-4 Setting for serial communications

When "PARALLEL+SERIAL+USB" (general purpose serial) has been specified in item "
I/F" on the "I/O CONDITIONS" menu (page 17-1), and when "SERIAL" or "PC-LINK" has been
specified in item "
"COMM.SET" screen.
Set the items to match the communication conditions of the other device.
Select "MAIN COND" -> "SYS-CND" ->
"COMM.SET," in that order.
How to set the communication settings
Adjust each item to match the equipment used
to communicate.
COMM. STANDARD
Select "RS232C," "RS422:4LINE," or
"RS422:2LINE."
BAUD RATE (kbps)
Set the communication speed: 2.4 Kbps, 4.8
Kbps, 9.6 Kbps, 19.2 Kbps, 38.4 Kbps, 57.6
Kbps, or 115.2 Kbps.
NO.OF DATA BITS
Select either 7-bit or 8-bit.
PARITY CHECK
Select "EVEN," "ODD," or "NO."
NO.OF STOP BITS
Set it to 1-bit or 2-bits.

STATION NO.

Select the station number for communication using the up and down arrow keys.
OUT I/F (PARAL.)" the serial communication conditions must be set on the
21-23
Setting the Input/Output Conditions
SELECT SYSTEM COND
SYS-CND
I/O CONDITIONS
COMM.SET
COMPUTER LINK
GAIN-OFFSET
TIME
CAMERA TYPE
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
COMM.SET SCREEN COND SAVE
1COMM.STANDARD
RS232C
2BAUDRATE(k.bps)
115.2
3NO. OF DATE BITS
7BIT
7BIT
4PARITY CHECK
8BIT
EVEN
5NO. OF STOP BITS
2BIT
EVEN
6STATION NO.
00(0~7F)
ODD
NO
2BIT
1BIT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
MEAS INP
COLOR F C1 BRT
1COMM.STANDARD
2BAUDRATE(k.bps)
3NO. OF DATE BITS
4PARITY CHECK
5NO. OF STOP BITS
6STATION NO.
COLOR F C1 BRT
RS232C
RS422:4LINE
RS422:2LINE
2.4
4.8
9.6
19.2
38.4
57.6
115.2
21

Advertisement

Table of Contents
loading

Table of Contents