Setting the Input/Output Conditions
(1) Measurement start input = parallel, object type change = parallel, result output = parallel
Setting order 1 (
I/O CONDITIONS
1MEAS INP I/F
2OUT I/F(PARAL.)
- The conditions for outputting the results to the output signals Y0 to Y7 are set by the PC function. (See
"Chapter 20: PC Function.")
Time chart
Measurement
start input
(X0)
Type selection
input
READY output
When you set the READY
ON signal to "CAPTURE
COMPLETE."
- See page 21-3.
When you set the
READY ON signal to
"MEAS COMPLETE."
- See page 21-3.
PC calculation
condition
Parallel output
(Y0 to Y7)
21
Note: When the READY signal is turned ON, the measurement start input will be enabled. To detect the
end of the measurement, you have to create a ladder circuit pointing at the Y output for auxiliary
relay C119 (end of the measurement).
Custom
2)
PARALLEL+SERIAL+USB
TRIG CCD START
NO
PC-LINK
SERIAL
10 ms
or more
10 ms
10 ms
or more
or more
Specified object type number
Image
Image capture
disposition
Image
Image capture
disposition
P
P
P
P
Halt PC operation during
C
C
C
C
measurement
When the object type is
changed, all Y output and
auxiliary relays turn OFF.
utput condition
C119
End of the measurement
Configuration example
Camera 1 (image capturing)
Camera 2 (image capturing)
Remote keypad
Controller
Power supply
(24 V DC)
Warning lamp
External output
(Y0 to Y7)
Specified object type number
End of the measurement
Halt PC operation during
P
P
P
P
P
P
P
P
C
C
C
C
C
C
C
C
measurement
Parallel output is valid for PC control
after the measurement result is
determined.
Result output
Y00
21-6
Monitor
External trigger X0
(photo sensor or
proximity sensor)
Type select switch
-See page 21-5.
P
P
P
P
P
C
C
C
C
C
Result output