Remove the seal which fixes the harness.
Note:
Attach the seal by following the procedure
below.
-
Place the flat harness along the edge
of the scanner base.
-
Align the seal with the two edges of
the scanner base.
(4)
Lift up the CIS unit, disconnect 1 connector
on the bottom of the CIS unit, and then take
off the CIS unit.
Notes:
Take care not to contaminate the CIS unit
surface with fingerprints, dust or such.
Be sure to perform "05-310" with the
platen cover or the ADF/RADF closed
after replacing the CIS unit.
(5)
Release 2 latches each to take off 2 original
glass guides from the CIS unit.
e-STUDIO182/212/242
SCANNER
Seal
Harness
CIS unit
Original glass guide
© 2009 TOSHIBA TEC CORPORATION All rights reserved
6 - 22
Fig. 6-28
Connector
Fig. 6-29
Fig. 6-30