7. Abnormality detection by the thermistors
The following table shows the conditions judging the fuser roller temperature abnormality and
detecting timing.
Checking
Priority
timing
On usual
1
Detecting 40°C
1
Detecting 100°C
1
2
Detecting
1
warming-up
temperature
2
During ready
1
status
2
During copying
1
2
*
The figures in the "priority" section denote the priority of error checking.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Temperature judged
Center
Side
thermistor
thermistor
230°C or above
-
230°C or above
-
40°C or below
-
40°C or below
100°C or below
-
100°C or below
40°C or below
150°C or above
150°C or above
40°C or below
Warming-up temp.
or below
-
Warming-up temp.
or below
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
-
40°C or below
40°C or below
-
40°C or below
-
12 - 11
Edge
thermistor
-
-
-
-
230°C or above
-
-
-
-
-
-
-
-
-
-
-
-
-
40°C or below
-
-
40°C or below
-
-
-
-
-
-
-
40°C or below
Error-
Error
judging
code
timing
On usual
C44
Specified
C41
time
Specified
C44
time
On usual
C43
Specified
C44
time
On usual
C43
On usual
C43
C44
On usual
C44
C45
e-STUDIO182/212/242
FUSER / EXIT UNIT
12