(4)
Remove 2 E-rings. Then remove the gear,
cover, spring and cam out of the shaft.
Note:
When assembling the bypass pickup clutch,
be sure to adjust the position of the hook of
the spring and cover so that the center slit of
the cover and the center of the cam are
aligned.
(5)
Remove 1 E-ring, and take off the bypass
feed clutch.
(6)
Remove the gear, cover, spring and cap.
© 2009 TOSHIBA TEC CORPORATION All rights reserved
Spring
Cover
Gear
E-ring
Fig. 9-27
Cover
Spring
Fig. 9-28
E-ring
Bypass feed clutch
Fig. 9-29
Cover
Gear
Fig. 9-30
9 - 17
E-ring
Cam
Shaft
Hook
Cam
Cap
Spring