Toshiba e-STUDIO182 Service Manual page 162

Hide thumbs Also See for e-STUDIO182:
Table of Contents

Advertisement

(7)
Take off the bracket of paper empty sensor.
P.9-18 "9.5.11 Paper empty sensor (S7)"
(8)
Release the harness from the harness
clamp, disconnect the connector, remove 3
screws, and then take off the registration
guide.
(9)
Remove the seal, release 2 latches, and take
off the registration sensor.
e-STUDIO182/212/242
PAPER FEEDING SYSTEM
Connector
Registration sensor
© 2009 TOSHIBA TEC CORPORATION All rights reserved
9 - 26
Registration guide
Fig. 9-55
Seal
Fig. 9-56

Hide quick links: