10.7.6

Main charger cleaner

(1)
Take off the main charger.
P.10-13 "10.7.4 Main charger"
(2)
Release the hook of the cleaning shaft. Then
rotate the shaft at 90 degrees to take it off.
10.7.7

Needle electrode

(1)
Take off the main charger grid and main
charger cleaner.
P.10-13 "10.7.5 Main charger grid"
P.10-14 "10.7.6 Main charger cleaner"
(2)
Take off the terminal covers of both front and
rear sides.
(3)
Remove the terminal and spring. Then take
off the needle electrode.
Notes:
1. Do not touch the needle electrode directly
with bare hands.
2. Make sure not to hold or bend the needle
electrode.
e-STUDIO182/212/242
DRUM RELATED SECTION
Main charger cleaner
Needle electrode
© 2009 TOSHIBA TEC CORPORATION All rights reserved
10 - 14
Fig. 10-19
Terminal cover
Fig. 10-20
Terminal
Spring
Fig. 10-21