Panasonic UF-6300 Service Manual page 160

Table of Contents

Advertisement

5.1.4.2.
Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Step
1
Standby
2
Press "FUNCTION" and then "7".
3
Press "MONITOR" four times, then press "*".
4
Press "4".
5
Press "2" and "START".
6
Enter the signal number (1-7) to select the binary signal.
Press "CLEAR" to end the signal generation. To select another signal,
7
repeat step 6.
8
Press "STOP" twice to return to standby.
Service Mode 4 - Tonal Signal
Operation or Unit Condition
Tonal Signal Table
Number
1
2
3
4
5
6
7
Signals
462 Hz
1080 Hz
1100 Hz
1300 Hz
1650 Hz
1850 Hz
2100 Hz
160
LCD Display
MMM-dd-yyyy
15:00
00%
SET MODE
(1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
MODEM TEST (1-5)
1:SIGNAL TEST
TONAL TEST
IDLE (ENTER 1-7)
TONAL TEST
1080Hz
TONAL TEST
IDLE (ENTER 1-7)
MMM-dd-yyyy
15:00
00%

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-5300Uf-6200

Table of Contents