4.13 Use the count function

4.13.1 Print count characters
(1) Count characters
●Prints by changing the count value in the specified increments at each printing.
Value
Range (minimum, maximum)
Update (In progress)
Update (Units)
Increment
Direction
Jump
(Jump from, Jump to)
Reset
Count skip
Zero-suppression
Multiplier
●A series of count characters is called a "Count block".
Model type
UX-B
UX-D
UX-E
(Maximum digit : 20 digits/count block)
●The count conditions are set for each count block.
●When there are multiple count blocks, the count conditions are set for each count block and each is
updated independently. There is no carry from another count block.
4-61 ●Use the count function
Count conditions screen setup items
Setup item
Maximum Count block count
Maximum Count block count
(Option : Up to 8)
Count value to be printed next.
Range of count value. Set for each digit.
Number of printings after the last count update.
Count update printing cycle. Count is updated each printing the
number of update units.
Change value of count value at count update.
Selects whether counted up or counted down at count update.
After the count value matches the "Jump from:", the next count
value is made the "Jump to:".
When Count reset of the Print description screen is pressed, the
count value is changed to the specified value.
Set capital alphabetical characters, small alphabetical characters
or user patterns to skip in count block.
Selects whether or not leading 0 except the rightmost end is to be
replaced by a space.
The value input here is multiplied by the count value and the
result is made the print contents.
3
3
8
Contents