(27) SOFT SWITCH: #27

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
Reserved
4
3
2
Immunity for dial
tone receiver
1
• Bit 1-4: Line input energy must be lower this level before dialing.
Function
Reserved
Reserved
Reserved
Reserved
Level (dBm)
0 -1 -2 -3 -4 -5 -6 -7
Bit 4
0
0 0
Bit 3
0
0 0
Bit 2
0
0 1
Bit 1
0
1 0
Level (dBm)
-8 -9 -10 -11 -12 -13 -14 -15
Bit 4
1
1 1
Bit 3
0
0 0
Bit 2
0
0 1
Bit 1
0
1 0
S-130
Initial
Setting
Bit HEX
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
0
0
1
1
1
0
1
0
1
0
1
1
1
1
1
0
0
1
1
1
1
1
0
0
1
1
1
0
1
0
1