Soft Switch: #29 - NEC NEFAX 671 Service Manual

Hide thumbs Also See for NEFAX 671:
Table of Contents

Advertisement

(29) SOFT SWITCH: #29

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
4
3
2
Time to dial after
size the line when
dial tone detected
(Unit = 200 ms)
1
Function
Reserved
Reserved
Reserved
Time
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
(sec)
Bit 5
0
0
0
0
0
Bit 4
0
0
0
0
0
Bit 3
0
0
0
0
1
Bit 2
0
0
1
1
0
Bit 1
0
1
0
1
0
Time
2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8
(sec)
Bit 5
0
0
0
0
0
Bit 4
1
1
1
1
1
Bit 3
0
0
1
1
1
Bit 2
1
1
0
0
1
Bit 1
0
1
0
1
0
Time
4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8
(sec)
Bit 5
1
1
1
1
1
Bit 4
0
0
0
0
1
Bit 3
1
1
1
1
0
Bit 2
0
0
1
1
0
Bit 1
0
1
0
1
0
Time
6.0 6.2
(sec)
Bit 5
1
1
Bit 4
1
1
Bit 3
1
1
Bit 2
1
1
Bit 1
0
1
S-132
Initial
Setting
Bit HEX
0
0
1
0
1
0
0
0
0
0
0
1
0
0
0
1
1
0
1
1
1
0
0
0
1
1
0
0
1
0
1
0
1
0
1
1
1
1
1
0
0
0
0
1
0
0
0
0
1
0
0
1
1
1
0
1
0
1
4
0
1
1
1
1
1
1
1
1
1
1
0
0
0
1
1
0
1
1
0
0
1
0
1
0
1