Bit
Designation
No.
"0"= Invalid
"1"= Polling subaddress transmission (DTC) by
35
Polled SubAddress (DIS)/PSA
"0"= Invalid
36
"1"= T.43 coding
"0"= Invalid
37
"1"= Plane interleave
38 Set to "0"
39 Set to "0"
"0"= Without
40 Extend field
"1"= With
"0"= Invalid
41
"1"= R8 x 15.4 lines/mm
"0"= Invalid
42
"1"= 300 x 300 pels/25.4 mm
"0"= Invalid
43
"1"= R16 x 15.4 lines/mm and/or 400 x 400 pels/25.4 mm
"0"= Invalid
44
"1"= Inch based resolution preferred
"0"= Invalid
45
"1"= Metric based resolution preferred
Minimum scan
"0": T 15.4 = T 7.7
line time capabil-
"1": T 15.4 = 1/2 T 7.7
46
ity for higher res-
olutions.
"0"= Invalid
47
"1"= Selective polling (DIS)/ Selective polling trans-
mission (DTC)
0: Without
48 Extend field
1: With
"0"= Invalid
49
"1"= Sub Addressing capability
"0"= Invalid
50
"1"= Password/ Sender Identification capability
(DIS)/ Password transmission (DTC)
"0"= Invalid
51
"1"= Ready to transmit a data file (polling)
52 Set to "0"
"0"= Invalid
53
"1"= Binary File Transfer (BFT)
DIS/ DTC
Set to "0"
Resolution type selection
"0"= metric based resolution
"1"= inch based resolution
Do not care
Do not care
Set to "0"
"0"= Invalid
"1"= Sub Addressing transmis-
sion
"0"= Invalid
"1"= Sender Identification trans-
mission
Set to "0"
S-164
DCS

Advertisement