Details Of Maintenance Mode Functions; Initialize Eeprom Parameters (Function Code: 01, 91) - Brother ADS-2600W Service Manual

Hide thumbs Also See for ADS-2600W:
Table of Contents

Advertisement

1.3

Details of Maintenance Mode Functions

1.3.1 Initialize EEPROM parameters (function code: 01, 91)

<Function>
This function is used to initialize the setting values for operation parameters, user switches,
and worker switches (WSW) registered in the EEPROM. Entering function code 01 initializes
most EEPROM areas. Entering function code 91 initializes only the specified areas as shown
in the table below.
Data item
Counter information
Error history
MAC address
Worker switches
User switches (items initialized when
"Factory Reset" is executed)
Function settings except user switches
(settings not subject to "Factory Reset")
LAN setting
<Operating Procedure>
(1) Press the [0] and [1] keys in this order in the initial state of maintenance mode to display
"Maintenance 01" (or press the [9] and [1] keys as appropriate to display "Maintenance
91") on the LCD.
(2) Press the [SET] key. "PARAMETER INIT" is displayed on the LCD.
(3) When initializing parameters is completed, the machine returns to the initial state of
maintenance mode.
Function code
Areas not to be
Areas to be initialized
5-4
01
Areas not to be
initialized
Areas to be initialized
91
initialized
Confidential