Error code CB00 to CF00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code D000
---
An error occurred while initializing the touch panel.
Step
Connection failure of the touch
1
panel PCB harness
2
Touch panel PCB failure
3
Main PCB failure
Error code D100 to DF00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code E000
---
An error occurred in the ROM check sum.
Step
1
Main PCB failure
Cause
Replace the main PCB ASSY.
Cause
Reconnect the touch panel PCB harness.
Replace the touch panel PCB ASSY.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
2-21
Remedy
Remedy
Remedy
Remedy