1.3.9 Change USB No. return value / Adjust left-end print start position on second side when
duplex printing (function code: 45)
 Change USB No. return value
<Function>
When the operating system (OS) installed on the computer is Windows Vista
machine is connected to this computer using USB2.0FULL, the OS may not be able to obtain
the USB device serial number depending on the computer and USB device. If the serial
number cannot be obtained, the number of devices increases each time the device is
connected to the computer. To avoid this problem, setting this function to "USBNo.=ON" can
fix the USB No. return value to "0".
LCD
USBNo. = ON
USBNo. = OFF
The setting currently selected is marked with "*" at the end of the display.
<Operating Procedure>
(1) Press the [4], and then the [5] key in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
(2) Press the [SET] key. "USBNo.=ON*" is displayed on the LCD.
(3) Press the [
value to "0" or "USBNo.=ON" when not fixing it.
(4) Press the [SET] key. "Accepted" is displayed on the LCD, and the machine returns to the
initial state of maintenance mode.
(5) Turn OFF the power switch.
Note:
• The setting is applied after the power switch is turned OFF and then ON again.
 Adjust left-end print start position on second side when duplex printing
<Function>
In the event that the left-end print start position deviates on the second side when duplex
printing, use this function to adjust the position left/right.
The adjustable range is -100 to 750 (unit: 300 dpi). (Shifted to left when the value is negative)
<Operating Procedure>
(1) Press the [4], and then the [5] key in the initial state of maintenance mode. "USBNo." is
displayed on the LCD.
(2) Press the [
(3) Press the [SET] key. "DX.XAdjust=**" is displayed on the LCD.
(The value currently set is displayed for **.)
(4) To shift the writing start position to the left, press the [
shift the position to the right, press the [
(5) Press the [SET] key. "Accepted" is displayed on the LCD, and the machine returns to the
initial state of maintenance mode.
Returns the serial number of the machine. (Default)
Returns "0".
] or [
] key to display "USBNo.=OFF" when fixing the serial number return
] or [
] key to display "DX.XAdjust" on the LCD.
Description
] key to decrease the value. To
] key to increase the value.