Error code E700 to EC00
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code ED00
Print Unable ED
Communication between the wireless LAN PCB and the main PCB cannot be established at
machine startup.
Step
Connection failure of the wireless
1
LAN PCB harness
2
Wireless LAN PCB failure
3
Main PCB failure
Error code EE00
Print Unable EE
Detected communication failure after communication between the wireless LAN PCB and the
main PCB was established.
Step
1
Wireless LAN PCB failure
2
Main PCB failure
Error code EF00 to F800
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
---
An unidentified error occurred.
Step
1
Main PCB failure
Error code F900
---
The country code was not entered correctly.
Step
The country code was not
1
entered correctly.
Cause
Replace the main PCB ASSY.
Cause
Check the connection of the wireless LAN PCB
harness, and reconnect it if necessary.
Replace the wireless LAN PCB ASSY.
Replace the main PCB ASSY.
Cause
Replace the wireless LAN PCB ASSY.
Replace the main PCB ASSY.
Cause
Replace the main PCB ASSY.
Cause
Reenter the country code. (Refer to
Setting by country (function code: 74)" in
Chapter
2-24
Remedy
Remedy
Remedy
Remedy
Remedy
5.)