Toshiba TOSVERT VF-AS3 Instruction Manual page 130

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Memo
4
2) Direct access
A 4-digit communication number is input to specify
a parameter, and its setting screen is displayed
directly.
On this setting screen, you can check or change
the setting value of the parameter.
When you select "2. Direct access" on the [Setting
mode] screen and press the [OK] button, the direct
access screen is displayed.
A 4-digit communication number is displayed.
The selected digit is highlighted.
On the lower side of the screen, the title, name,
9
and setting value of the parameter corresponding to the communication number are displayed.
Input the communication number in the following procedure.
1
Set the digit.
When you press the [F2] key
character is shifted to the left. When you press the
[F3] key
the right.
4. [Basic operation] Operation methods of motor
• The following parameters are not displayed in the history function.
<FC: Panel run frequency>
<AUF: Guidance function>
<AUA: Application easy setting>
<AUL: Multi-rating select>
<AU1: Automatic Acc/Dec>
<AU2: Torque boost macro>
<SEt: Region setting check>
<tyP: Default setting>
<F699: Trip for test>
<F700: Parameter reading&writing access lockout>
<F737: Panel keys lockout>
<F738: Password setting>
<F739: Password verification>
<F899: Communication option reset>
, the highlighted character is shifted to
F100
Top View
, the highlighted
F100
Top View
4-6
E6582062
STOP
0.0Hz
Direct access
Set the communication number
0
1
0 0
: Low-speed signal freq
0.0Hz
Monitor
STOP
0.0Hz
Direct access
Set the communication number
0 1 0
0
: Low-speed signal freq
Monitor
14:02
14:02
0.0Hz