Toshiba TOSVERT VF-AS3 Instruction Manual page 83

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

■ With frame size A4
VFAS3-2110P to 2185P, VFAS3-4220PC to 4370PC
1
Remove the front cover.
For how to remove, refer to [2. 2. 2].
2
Remove the screw(s) for switching of grounding capacitor
from the position of the grounding mark and insert it/them
into the position of the non-grounding mark.
The 240 V class has one screw.
The 480 V class has two screws. Remove both of two
screws.
The grounding capacitor is disconnected.
3
To recover the shipping state, remove the screw(s) for
switching of grounding capacitor and tighten it/them to the
screw hole in the position of the grounding mark.
The grounding capacitor is connected and grounded.
4
After switching, mount the front cover.
For how to mount, refer to [2. 2. 2].
• For models with two switching screws, be sure to set both screws to the same side.
Important
Grounding
Screw
Screw
Non-
grounding
2-49
E6582062
Grounding mark
Nongrounding mark
240V class
480V class
240V class
480V class