Toshiba TOSVERT VF-AS3 Instruction Manual page 95

High-performance industrial inverter for 3-phase motors, 3-phase 240v class 0.4 to 55kw, 3-phase 480v class 0.4 to 280kw
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

2. 3. 8
Mounting of DC reactor
• Mount the attached DC reactor (DCL) for VFAS3-4160KPC ~ 4280KPC.
If you do not mount the attached DC reactor (DCL), it will result in malfunction. Mount the DC
reactor (DCL) between [PA/+] and [PO].
Mandatory
action
This inverter is equipped with a DC reactor (DCL) as standard, however, for VFAS3-4160KPC to
4280KPC, it is packaged together with the unit.
After installing the inverter, mount the DC reactor in the following procedure.
■ With frame size A7
VFAS3-4160KPC
1
Remove the front cover (upper) of the inverter unit in advance.
For how to remove, refer to [2. 2. 5].
2
Remove four screws of the DC reactor cover of the DC
reactor.
Store the removed screws so as not to be lost.
3
Remove the DC reactor cover from the DC reactor by pulling
it down.
The upper side of the DC reactor cover is to be inserted.
Caution
2-61
E6582062
DC reactor cover
Screw
DC reactor cover
pulling
down
2. Installation and wiring
2
3
9
10