6. 25. 3
Selecting tension control torque bias input and load
sharing gain input
<F423: Tension control torque bias input>
<F424: Load sharing gain input>
<F727: Panel tension torque bias>
<F728: Panel load sharing gain>
■ Function
These parameters are used to select tension control torque bias input and load sharing gain input.
Tension control torque bias
■ Parameter setting
Title
Parameter name
F423
Tension control torque
bias input
F424
Load sharing gain input
F727
Panel tension torque bias
F728
Panel load sharing gain
Load sharing gain
Torque reference
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
4: Terminal AI4 (option)
5 - 11: -
12: F727
13 - 19: -
20: Embedded Ethernet
21: RS485 communication connector 1
22: RS485 communication connector 2
23: Communication option
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
4: Terminal AI4 (option)
5 - 11: -
12: F728
13 - 19: -
20: Embedded Ethernet
21: RS485 communication connector 1
22: RS485 communication connector 2
23: Communication option
-250 to +250
0 - 250
6-105
STOP
F727 : Panel tension torque bias
Min: -250
X1000
X100
Torque command
Adjustment range
6. [Advanced] How to use parameters
E6582062
0.0Hz
13:42
+0
%
Max: 250
X10
X1
Unit
Default setting
0
0
%
0
%
100
3
4
6
9