Communication
Title
Parameter name
No.
Parameter for
F339
0339
manufacturer
F340
0340
Creep time 1
F341
0341
Brake function
Load torque input
F342
0342
select
F343
0343
Hoisting torque bias
Lowering torque
F344
0344
bias rate
Brake releasing
F345
0345
time
F346
0346
Creep frequency
F347
0347
Creep time 2
F348
0348
Brake learning
F349
0349
Dwell operation
Acc suspended
F350
0350
frequency
F351
0351
Acc suspended time 0.0 - 10.0
Dec suspended
F352
0352
frequency
Dec suspended
F353
0353
time
Adjustment range
Unit
-
-
0.00 - 10.00
s
0: Disabled
1: Fwd hoisting
-
2: Rev hoisting
3: Horizontal operation
0: -
1: Terminal RR
2: Terminal RX
3: Terminal II
4: Terminal AI4 (option)
5 - 11: -
12: F343
13 - 19: -
20: Embedded Ethernet
-
21: RS485
communication
(connector 1)
22: RS485
communication
(connector 2)
23: Communication
option
-250 to +250
%
(F342 = "12" only)
0 - 100
%
0.00 - 10.00
s
F240 - 20.0
Hz
0.00 - 10.00
s
0: -
1: Enabled (0 after
-
execution)
0: Disabled
1: F350-F353 setting
-
2: Terminal input
0.0 - FH
Hz
s
0.0 - FH
Hz
0.0 - 10.0
s
11-17
Minimum
Write
setting unit
Default
during
(Panel/
setting
running
Communication)
*6
-
-
-
0.00
N
-
0
N
-
12
Y
100
Y
100
Y
0.05
Y
3.0
N
0.10
Y
-
0
N
-
0
N
0.0
Y
0.0
Y
0.0
Y
0.0
Y
11. Table of parameters