Updating iDRAC6 Firmware Using SM-CLP

To update iDRAC6 firmware using SM-CLP , you must know the TFTP URI
for the Dell update package.
Follow these steps to update the firmware using SM-CLP:
1 Log in to iDRAC6 using Telnet or SSH.
2 Enter "smclp" to start the SM-CLP console.
3 Check the current firmware version by entering the following command:
show -d properties
/admin1/system1/sp1/availablesw1/swid1
4 Enter the following command:
load -source tftp://<tftp-server>/<update-path>
/admin1/system1/sp1
where <tftp-server> is the DNS name or IP address of your TFTP server
and <update-path> is the path to the update package on the TFTP server.
Your Telnet or SSH session will be terminated. You may need to wait
several minutes for the firmware update to complete.
5 To verify that the new firmware was written, start a new Telnet or SSH
session and re-enter the show -d properties
/admin1/system1/sp1/availablesw1/swid1 command.