Getconfig - Dell iDRAC6 User Manual

Remote access controller 6
Hide thumbs Also See for iDRAC6:
Table of Contents

Advertisement

Examples
racadm config -g cfgLanNetworking -o
cfgNicIpAddress 10.35.10.110
Sets the cfgNicIpAddress configuration parameter (object) to the value
10.35.10.110. This IP address object is contained in the group
cfgLanNetworking.
racadm config -f myrac.cfg
Configures or reconfigures iDRAC6. The myrac.cfg file may be created
with the getconfig command. The myrac.cfg file may also be edited
manually as long as the parsing rules are followed.
NOTE:
in the file, you must enter them manually. If you want to remove passwords
from the myrac.cfg file during configuration, use the -p option.

getconfig

The getconfig subcommand allows you to retrieve iDRAC6 configuration
parameters individually, or all iDRAC6 configuration groups may be retrieved
and saved into a file.
Input
Table A-4 describes the getconfig subcommand options.
NOTE:
The -f option without a file specification will output the contents of the file to
the terminal screen.
Table A-4. getconfig Subcommand Options
Option
Description
-f
The -f <filename> option directs getconfig to write the entire iDRAC6
configuration to a configuration file. This file can then be used for batch
configuration operations using the config subcommand.
NOTE:
cfgIpmiPef groups. You must set at least one trap destination to capture the
cfgIpmiPet group to the file. Also, cfgIpmiPet and cfgIpmiPef will be saved
only by remote and telnet/ssh RACADM and not by local RACADM in this
current release.
338
RACADM Subcommand Overview
The myrac.cfg file does not contain passwords. To include passwords
The -f option does not create entries for the cfgIpmiPet and