Modbus address
№
Active Group
comm
1
2
3
4
5
231
22,278
232
22,279
233
22,280
234
22,281
235
22,282
236
22,283
237
22,284
238
22,285
239
22,286
240
22,287
241
22,400
242
22,401
243
22,402
244
22,403
245
21,632
246
21,648
247
21,888
248
21,889
249
21,890
250
21,924
251
21,920
252
21,921
253
21,922
254
21,923
255
21,810
256
21,760
257
21,761
258
21,762
259
21,763
260
21,764
261
21,765
262
21,766
263
21,767
264
21,768
265
21,769
266
21,771
267
21,772
268
21,773
269
21,774
270
21,775
271
21,776
272
21,816
273
21,824
274
21,825
275
21,826
276
21,828
277
21,829
278
21,830
279
21,786
280
21,787
Name
6
7
8
BISW7
BISW8
BISW9
BISW10
BISW11
BISW12
BISW13
BISW14
BISW15
BISW16
LED
LED1
LED2
LED3
LED4
Descriptio
Plant name
n
Description
Communic
Address-HDLC
ation
Address-IEC
Address-MOD
PRTCL1
232C
IECBR
IECBLK
MODBR
Record-
Phase mode
Fault
Record-
Mech.trip1
Event
record
Mech.trip2
Mech.trip3
Mech.trip4
Trip
Ind.Reset
Relay fail
CT1 err
CT2 err
CT3 err
Event1
Event2
Event3
Sys. Set change
Rly. Set change
Grp. Set change
Record-
Time
Disturbanc
e
1OCPS
2OCPS
3OCPS
1OCPG
2OCPG
3OCPG
TRIP1
TRIP2
190
Standard (Except Y-TYPE)
Range
Units
Contents
50Hz
60Hz
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
Norm - Inv
ditto
-
0 - 3071
Configrable LEDs
-
0 - 3071
ditto
-
0 - 3071
ditto
-
0 - 3071
ditto
-
Specified by user
Plant name
Memorandum for
-
ditto
user
Relay ID No. for
-
1 - 32
RSM
Relay ID No. for
-
1 - 254
IEC103
Relay ID No. for
-
1 - 247
MODBUS
RS485 Port Comm.
HDLC - IEC103 - MODBUS
Protocol
Comm. speed for
9.6 - 19.2 - 38.4 - 57.6
-
RSM
-
9.6 - 19.2
-
Normal - Block
Comm speed for
9.6 - 19.2
-
Modbus
Phase indication of
-
Operating - Fault
Fault recording
-
None - Operate - Reset - Both
Event record trigger
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate - Reset - Both
ditto
-
None - Operate
ditto
-
None - Operate
ditto
-
None - Operate
ditto
0.1 - 3.0
s
Disturbance record
OC element for
0.10 - 20.00
pu
disturbance
recorder initiation
0.10 - 20.00
pu
0.10 - 20.00
pu
0.05 - 20.00
pu
0.05 - 20.00
pu
0.05 - 20.00
pu
-
Off - On
Disturbance trigger
-
Off - On
ditto
6 F 2 S 0 7 8 9
Default Setting of Relay Series
(50Hz / 60Hz)
2-Winding
3-Winding
User Setting
101B
102B
201B
202B
Norm
Norm
Norm
Norm
Norm
Norm
Norm
Norm
Norm
Norm
0
0
0
0
Specified by user
Specified by user
1
2
1
HDLC
9.6
19.2
Normal
19.2
Operating
Both
Both
Both
Both
Both
Both
Both
Both
Both
--
Both
Both
Both
Both
Operate
Operate
Operate
1.0
1.00
1.00
--
1.00
1.00
1.00
--
1.00
On
On