Protection zones
Identifier
Parameter
1.
CPROT
INT:
Number of the
protection
zone
NPROT
INT:
Number of the
protection
zone
Preprocessing / single block
Identifier
Parameter
STOPRE
SBLOF
SBLON
Fundamentals
Programming Manual, 01/2015, 6FC5398-1BP40-5BA2
2.
3.
INT: Option
REAL: Offset
of the protec‐
0: Protection
tion zone in
area OFF
the first geom‐
1: Preactivate
etry axis
protection
zone
2: Protection
area ON
3: Preactivate
protection
zone with con‐
ditional stop,
only with pro‐
tection zones
active
INT: Option
REAL: Offset
of the protec‐
0: Protection
tion zone in
area OFF
the first geom‐
1: Preactivate
etry axis
protection
zone
2: Protection
area ON
3: Preactivate
protection
zone with con‐
ditional stop,
only with pro‐
tection zones
active
17.5 Predefined procedures
4.
5.
REAL: Offset
REAL: Offset
of the protec‐
of the protec‐
tion zone in
tion zone in
the second
the third ge‐
geometry axis
ometry axis
REAL: Offset
REAL: Offset
of the protec‐
of the protec‐
tion zone in
tion zone in
the second
the third ge‐
geometry axis
ometry axis
Explanation
Preprocessing stop until all prepared blocks in the main
run are executed
Suppress single-block processing
Cancel suppression of the single-block processing
Tables
Explanation
Channel-specific pro‐
tection zone ON/OFF
Machine-specific pro‐
tection zone ON/OFF