Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
6.2 Chassis
6.2.2.4

Technical data

Table 6- 8
Technical data, sine-wave filter
Article number
Suitable for
Power Module
Unit rating of the Power
Module at a 4 kHz pulse
frequency
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- to the Power Module
- to the load
- PE
Max. permissible cable length
between sine-wave filter and
motor
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
200
6SL3000-
2CE32-3AA0
6SL3310-
1TE32-1AA.
kW
90
A
225
kW
0.35
kW
0.6
M10 connecting lugs
M10 connecting lugs
M10 drill hole
m
300 (shielded)
450 (unshielded)
IP00
mm
620
mm
300
mm
320
kg
124
2CE32-3AA0
2CE32-8AA0
1TE32-6AA.
1TE33-1AA.
110
132
225
276
0.35
0.4
0.6
0.69
IP00
IP00
620
620
300
300
320
320
124
127
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
2CE33-3AA0
2CE34-1AA0
1TE33-8AA.
1TE35-0AA.
160
200
333
408
0.245
0.38
0.53
0.7
IP00
IP00
620
620
370
370
360
360
136
198