8.1 Sensor Modules
X520 encoder system interface
Table 8- 13
X520: Encoder system interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type:
15-pin Sub-D socket
Measuring current via temperature sensor connection: 2 mA
1) Accuracy of the temperature measurement:
- KTY: ±7 °C (including evaluation)
- PT1000: ±5 °C (PT1000 tolerance class B according to DIN EN 60751 including evaluation)
- PTC: ±5 °C (including evaluation)
NOTICE
Damage to the encoder due to incorrect supply voltage
The encoder supply can be parameterized to 5 V or 24 V. Incorrect parameter assignment
can cause damage to the encoder.
• Select the appropriate supply voltage.
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
310
Signal name
+ Temp
1)
Clock
Clock*
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P sense
M encoder (M)
- Temp
1)
M sense
R
R*
B*
B
A* / data*
A / data
Technical data
Temperature sensor KTY84-1C130 / PT1000 / PTC
SSI clock
Inverse SSI clock
Encoder power supply
Sense input encoder power supply
Ground, encoder power supply
Temperature sensor KTY84-1C130 / PT1000 / PTC
Ground sense input
Reference signal R
Inverse reference signal R
Inverse incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data