Connection Methods; Drive-Cliq Signal Cables; Overview - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Danger to life through a hazardous voltage when connecting an unsuitable power supply
Touching live components can result in death or severe injury.
• Connect the ground potential to the PE conductor connection.
• Mount the power supply close to the drive lineup.
10.6

Connection Methods

10.6.1

DRIVE-CLiQ signal cables

10.6.1.1

Overview

To connect DRIVE-CLiQ components, various pre-assembled and non-assembled DRIVE-
CLiQ signal cables are available. The following pre-assembled DRIVE-CLiQ signal cables
will be discussed in more detail in the next sections:
● Signal cables without 24 V cores with RJ45 connectors
● MOTION-CONNECT signal cables with DRIVE-CLiQ connectors
● MOTION-CONNECT signal cables with DRIVE-CLiQ connector and M12 socket
Table 10- 6
Type of DRIVE-CLiQ signal
cable
6SL3060-4A..
6FX2002-1DC..
6FX5002-2DC00..
to .. -2DC20..
6FX8002-2DC00..
to .. -2DC20..
6FX5002-2DC30..
6FX8002-2DC30..
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
WARNING
Ideally, they should be mounted on a common mounting plate. If different mounting
plates are used, they must be electrically connected in compliance with the
Configuration Manual, "EMC installation guideline".
Overview of pre-assembled DRIVE-CLiQ signal cables
Cabinet design and EMC for components, Blocksize format
24 V cores
Degree of protection
IP20
--
x
x
x
x
X
(DRIVE-CLiQ)
10.6 Connection Methods
Connector type
IP67
x
RJ45
x
DRIVE-CLiQ
X
DRIVE-CLiQ /
(M12)
M12
361

Advertisement

Table of Contents
loading

Table of Contents