Scan Information Window; Priority; Priority Channel; Look Back Time A - Kenwood TKR-750 Programming Reference Manual

Hide thumbs Also See for TKR-750:
Table of Contents

Advertisement

6 EDIT MENU
6.6

Scan Information Window

It can configure the Scan operation and conditions on the
"Scan Information" window. (Refer to FUNC 16 Scan.)
Figure 6-13 Scan Information window
6.6.1

Priority

This is a priority channel type to be scanned periodically.
You can select the mode from None, Fixed, and Selected
from the dropdown list.
TKR-750/850/751/851 scans channels in numerical order
(Normal Scan) when the priority scan function is selected
None.
None
Not perform the Priority Scan.
The channels configured as the priority
Fixed
channel are scanned periodically.
Range
The selected channel is configured as
Selected
the priority channel when changing the
channel.
Default None
Note:
! You cannot configure the Priority Channel, Look Back Time A,
and Look Back Time B when priority is configured as "None".
! You cannot configure the Priority Channel when priority is
configured as "Selected".
6.6.2

Priority Channel

This is a channel to be scanned periodically when TKR-
750/850/751/851 is scanning.
Select the channel configured as the Priority Channel
from the dropdown list or directly enter the channel
number.
Range
1 - 16
Default
None
Note:
39
! You cannot configure this function if the "Priority" is configured to
"None" or "Selected".
! The dropdown list only displays the channel having the
configuration data.

6.6.3 Look Back Time A

This is a interval time to check the priority channel when
the scan is stopping on the normal channel and no signal
is on the priority channel. Configure the period by the spin
buttons or directly enter the value to configure the period.
In steps of
Default
Note: It pauses on the Priority Channel when there is a signal to

6.6.4 Look Back Time B

This is a interval time to check the priority channel when
the scan is stopping and a signal without same signalling
is on the priority channel. Configure the period by the spin
buttons or directly enter the value to configure the period.
In steps of
Default
Note: It pauses on the Priority Channel when there is a signal to
6.6.5
This is a condition of channel to transmit during scanning.
Select the condition from the dropdown list.
Default
Field Programming Reference (FPRG)
Range
0.5 - 5.0 sec.
0.1 sec.
0.5 sec.
receive and the signalling matches while scanning the
Priority Channel.
Range
0.5 - 5.0 sec.
0.1 sec.
2.0 sec.
receive and the signalling matches while scanning the
Priority Channel.

Revert Channel

Last Called
Last Used
Selected
Range
Selected + Talkback
Priority
Priority + Talkback
Last Called
Version: 1.01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tkr-851Tkr-850Tkr-751

Table of Contents